Gas Permeability Analyzer can tests the O2, CO2, N2 etc. gas transmission rate of plastic film, composite film, aluminum foil, thin sheets, rubber, porcelain, solar panel, medical patch and so on.

 

Working Principle

Differential-pressure method. Test sample separates test chamber into upper room and lower room, between which keeps a constant pressure difference (100KPa). Gas molecules penetrate through sample from higher pressure room into lower pressure room; measure the pressure change in lower pressure room and calculate gas transmission rate.

 

Gas Permeability Analyzer can tests the O2, CO2, N2 etc. gas transmission rate of plastic film, composite film, aluminum foil, thin sheets, rubber, porcelain, solar panel, medical patch and so on.

 

Working Principle

Differential-pressure method. Test sample separates test chamber into upper room and lower room, between which keeps a constant pressure difference (100KPa). Gas molecules penetrate through sample from higher pressure room into lower pressure room; measure the pressure change in lower pressure room and calculate gas transmission rate.

 

Standards

GB/T 1038, ISO 2556, ISO 15105-1, ASTM D1434

 

Features

  • Three test chambers, each with independent sensor and test data; can test three samples (but one test gas) at the same time; each chamber can stop and change sample independently.
  • Professional sensor, high precision.
  • Automatic test, auto judgment, auto stop.
  • Automatically keep pressure difference between upper and lower chambers.
  • Advanced electromagnetic temperature control technology, program controlled, auto increase and decrease; integrated design; precision 0.01℃.
  • High precision, can test aluminum foil.
  • Three test modes: high barrier, low barrier and medium barrier test.
  • Can expand test range to 600000 cm3/m224h·0.1MPa.
  • Can run long time without maintenance; over pressure auto protection.
  • LCD display test data.
  • Profesional software, simple interface, easy to use; flexible setting of test process.
  • Real time display curves of transmission rate, pressure, differential pressure, temperature.
  • Can zoom and move curves freely, so as to make detail analysis.
  • Professional test report, can export file in Office, PDF format etc.
  • Calibrated by Standard Film or by pressure.

 

Specifications

Test range 0.02~50000 cm3/m2·24h·0.1MPa
Test precision 0.01 cm3/m2·24h·0.1MPa
Temperature range 15~35℃ (5~50℃ optional)
Temperature precision ±0.01℃
Vacuum degree <10Pa
Vacuum resolution 0.1Pa
Test pressure 0~0.2MPa
Gas source test gas, purity 99.999%, 0.2~0.8MPa
Gas port Φ6mm gas pipe
Test gas O2, CO2, N2 etc.
Test area 50.24 cm2
Sample size Φ110 mm
Sample thickness ≤2mm
Number of samples 1~3pcs
Instrument size 80×56×40cm

 

TYPE TEMPERATURE RANGE TESTING RANGE

(cm3/m2·24h·0.1MPa)

FEATURE
A 5~50℃ 0.005~50000 keep pressure difference function Remote Controlling and Operating
B 15~35℃ 0.02~50000 keep pressure difference function Vacuum  Pump made in Germany
C 23℃ 0.1~50000 / Vacuum Pump made in China

 

 

 

 

 

 

 

 

 

Configuration

 

Gas Permeability Analyzer, software, communication cable, power cable, sample cutter, gas pipes 2pcs, pipe connectors 2pcs, sealing grease, spanner, filter paper 9pcs, Standard Films 1 set

Optional: vacuum pump, pressure releasing valve, computer

User provide: gas source 

sample cutter        vacuum pump            pressure releasing valve

 

st range 0.02~50000 cm3/m2·24h·0.1MPa
Test precision 0.01 cm3/m2·24h·0.1MPa
Temperature range 15~35℃ (5~50℃ optional)
Temperature precision ±0.01℃
Vacuum degree <10Pa
Vacuum resolution 0.1Pa
Test pressure 0~0.2MPa
Gas source test gas, purity 99.999%, 0.2~0.8MPa
Gas port Φ6mm gas pipe
Test gas O2, CO2, N2 etc.
Test area 50.24 cm2
Sample size Φ110 mm
Sample thickness ≤2mm
Number of samples 1~3pcs
Instrument size 80×56×40cm

 

TYPE TEMPERATURE RANGE TESTING RANGE

(cm3/m2·24h·0.1MPa)

FEATURE
A 5~50℃ 0.005~50000 keep pressure difference function Remote Controlling and Operating
B 15~35℃ 0.02~50000 keep pressure difference function Vacuum  Pump made in Germany
C 23℃ 0.1~50000 / Vacuum Pump made in China